AI Nav

Brand > Type > Error code > E.04.10


How do you solve the E.04.10 error code on your Remeha Tzerra boiler?

Cause

Lockout due to failed burner start

Does your Remeha Tzerra boiler have an e.04.10 error code and you don't know what to do? Don't worry, we have all the answers for you! In this article we will guide you step by step in solving the e.04.10 error code on your Remeha Tzerra boiler, so that you can quickly enjoy the warmth and comfort in your home again.

The e.04.10 error code on the Remeha Tzerra boiler usually has to do with the ignition or the gas supply. This can have various causes, such as a clogged burner, a defective ignition pin or problems with the gas supply.

Don't worry if you're not technically minded, we'll walk you through what you need to do to resolve the e.04.10 error code. From checking the gas supply to cleaning the burner, we will discuss all possible solutions.

So what are you waiting for? Read on to learn how to fix the e.04.10 error code on your Remeha Tzerra boiler and quickly get back to enjoying a warm and comfortable home.

Introduction to the E.04.10 error code

Does your Remeha Tzerra boiler have an e.04.10 error code and you don't know what to do? Don't worry, we have all the answers for you! In this article we will guide you step by step in solving the e.04.10 error code on your Remeha Tzerra boiler, so that you can quickly enjoy the warmth and comfort of your home again.

The e.04.10 error code on the Remeha Tzerra boiler usually has to do with the ignition or the gas supply. This can have various causes, such as:

    clogged burner, a defective ignition pin or problems with the gas supply.


Don't worry if you are not tech savvy, we will explain step by step what you need to do to resolve the e.04.10 error code. From checking the gas supply to cleaning the burner, we discuss all possible solutions.

So read on to learn how to resolve the e.04.10 error code on your Remeha Tzerra boiler and quickly get back to enjoying a warm and comfortable home.

Understanding the Remeha Tzerra boiler

Before we dive into how to resolve the e.04.10 error code, it is important to learn more about the Remeha Tzerra boiler. This boiler is a popular choice due to its reliability and efficiency. It is important to understand how the boiler works so that you are better able to troubleshoot any problems.


The Remeha Tzerra boiler is a high-quality, condensing combination boiler that supplies both heat and hot water. It uses advanced technologies to ensure that you can always enjoy a comfortable indoor climate.

Common causes of the E.04.10 error code

Now that we have a better understanding of the Remeha Tzerra boiler, it's time to discuss the common causes of the e.04.10 error code. This error code can occur if there are problems with the ignition or the gas supply. Here are some common causes:


  1. Problems with the gas supply: A common cause of the e.04.10 error code is a problem with the gas supply. This could be due to a closed gas supply valve, a defective gas pressure regulator or other problems with the gas line.
  2. Defective ignition pin: The ignition pin is responsible for igniting the gas in the burner. If the ignition pin is defective, the boiler will not be able to ignite correctly and this will result in the e.04.10 error code.
  3. Clogged burner: If the burner is clogged, this can lead to incorrect ignition and thus cause the e.04.10 error code. This can be caused by dirt buildup or other contaminants in the burner.


Now that we have discussed the common causes of the e.04.10 error code, we can move on to the next section where we will discuss the solutions step by step.

Steps to troubleshoot error code E.04.10

Troubleshooting the e.04.10 error code on your Remeha Tzerra boiler can seem intimidating, but with the right steps you can tackle the problem effectively. Follow these steps to resolve the error code:



    Check the gas supply. Make sure that the gas supply valve is fully open and that there is sufficient gas pressure. Also check the gas line for any leaks. Check the ignition pin. Check that the ignition pin is properly aligned and free of dirt or damage. If the ignition pin is defective, it must be replaced. Clean the burner. If the burner is clogged, clean it thoroughly. Switch off the boiler and allow it to cool completely before cleaning the burner. Use a soft brush or vacuum cleaner to remove dirt and contaminants.


Follow these steps carefully and check after each step whether the e.04.10 error code is still present. If the error code still appears, you can continue to the next section where we discuss how to reset the Remeha Tzerra boiler.

Resetting the Remeha Tzerra boiler

If you are unable to resolve the e.04.10 error code, you can try resetting the Remeha Tzerra boiler. Resetting the boiler can help troubleshoot problems and restore normal operation. Follow these steps to reset the boiler:

    Turn off the boiler. Locate the on/off switch on the boiler and turn it off or unplug it. Wait at least 10 seconds before proceeding to the next step. Switch the boiler back on. Switch the boiler back on by pressing the on/off switch or by putting the plug back in the socket. Wait until the boiler has started and check whether the e.04.10 error code has disappeared.

If the error code is still present after resetting the boiler, it is advisable to seek professional help. A qualified heating engineer can investigate the problem further and provide the right solution.

Contact a professional for assistance

If you cannot resolve the e.04.10 error code yourself, it is important to call in a professional heating engineer. An experienced technician has the knowledge and expertise to accurately diagnose the problem and provide the right solution.

Contact a recognized heating company or find a certified Remeha service partner in your area. They can help you resolve the e.04.10 error code and ensure that your Remeha Tzerra boiler is functioning properly again.

Prevent the error code E.04.10 in the future

To prevent the e.04.10 error code from appearing again in the future, it is important to carry out regular maintenance on your Remeha Tzerra boiler. Here are some tips to keep the boiler in good condition:

    Have annual maintenance carried out by a professional technician. During maintenance, the technician will thoroughly inspect the boiler, clean it and resolve any problems before they cause major disruptions. Regularly check the gas supply. Make sure that the gas supply valve is fully open and that there is sufficient gas pressure. Also check the gas pipe for any leaks. Keep the burner clean. Clean the burner regularly to prevent dirt accumulation. Remove dirt and contaminants with a soft brush or vacuum cleaner.

By carrying out regular maintenance and keeping the gas supply and burner clean, you can significantly reduce the chance of the e.04.10 error code.

FAQs about the error code E.04.10

  • What is the cause of the E.04.10 error code on the Remeha Tzerra boiler?

    The e.04.10 error code can have several causes, such as a

  • Can I solve the E.04.10 error code myself?

    No, this malfunction requires the assistance of a co-certified professional.

  • How can I reset the Remeha Tzerra boiler?

    To reset the Remeha Tzerra boiler, switch the boiler off, wait 10 seconds and switch it back on.

Conclusion

Troubleshooting the e.04.10 error code on your Remeha Tzerra boiler may take some time and effort, but with the right steps you can tackle the problem effectively. Follow the troubleshooting steps mentioned above and consider seeking professional help if the problem persists. By carrying out regular maintenance and taking proper care of your Remeha Tzerra boiler, you can reduce the chance of error codes in the future and enjoy reliable heating and hot water supply in your home.

Manual information Remeha Tzerra error code E.04.10

Five failed burner starts:


(1) No ignition spark:


  • Check the wiring between the CU-GH and the ignition transformer


  • Check the ionization/ignition electrode


  • Check the breakdown to ground/earth


  • Check the condition of the burner deck


  • Check groundingReplace the CU-GH*



(2) Ignition spark but no flame formation:


  • Bleed the gas lines


  • Check air supply and flue gas discharge for blockages


  • Check whether the gas tap is properly opened


  • Check the gas supply pressure


  • Check correct operation and adjustment of gas valve. Check the wiring of the gas valve


  • Vervang of CU-GH*



(3) Flame but no or insufficient ionization:


  • Check whether the gas tap is properly opened


  • Check the gas supply pressure


  • Check the ionization/ignition electrode


  • Check grounding


  • Check the ionization/ignition electrode wiring.


    *CU-GH: Control Unit-Gas Hydraulic. This is a part of the boiler that is responsible for the regulation and management of the gas and hydraulic system. If there are problems with the ignition spark or flame formation, it may be necessary to check or replace the CU-GH.

This malfunction requires the help of a professional



From April 1, 2023, only certified companies may carry out work on gas combustion installations, such as central heating boilers, geysers, gas fireplaces and heaters.

Find an installer Back
Share by: